Simco - Fmx002 Manual Top

I can help you find products.

To ensure safe and highly accurate readings, connect the grounding lead from the side ground snap of the device to an earth-grounding point. Zeroing the Sensor:

| Specification | Details | | :--- | :--- | | | Low Range: 0 to ±1.49kV / High Range: ±1.0kV to ±20.0kV | | Ion Balance Range | 0 to ±200V (with optional charge plate) | | Accuracy | ±10% of full scale | | Measurement Distance | 25mm ± 1mm (1 inch) | | Power | 9V, 6F22 manganese battery | | Battery Life | >30 hours | | Response Time | 1 second | | Display Update | 5 times/second | | Auto Power-Off | After approx. 5 minutes of inactivity | | Dimensions (with battery) | 115mm x 65mm x 25mm (4.5" x 2.5" x 1") | | Weight (with battery) | 130g (4.6 oz) |

This overlapping point indicates exactly 1 inch of separation. Step 4: Reading and Holding Data simco fmx002 manual top

Follow these exact steps to obtain accurate, repeatable static measurements. Initial Preparation

| Icon | Meaning | Action Required | |------|---------|------------------| | 🔋 Battery outline | Low battery | Replace the 9V battery (top compartment) | | ⚠️ +/- sign | Polarity of charge | Positive (red zone) or Negative (blue zone) | | 📏 “cm” or “in” | Distance unit | Use the slider on the top side to switch | | 🎯 Circle with dot | Zeroing complete | Flashes during auto-zero | | | Reading locked | Press HOLD button again to release |

If the charge fluctuates or you cannot see the screen, press the green button. I can help you find products

Need to record a measurement in a hard-to-reach spot? The HOLD function is your answer.

This article provides a comprehensive overview of the FMX-002 fieldmeter, its operating procedures, technical specifications, and maintenance guidelines derived from industry standards. Key Technical Specifications Simco FMX-002 Go to product viewer dialog for this item.

Power Source: 9V battery, providing approximately 30 hours of continuous operation. Operational Guide: Step-by-Step 5 minutes of inactivity | | Dimensions (with

Simco (now part of Simco-Ion / Ion Systems ) typically provides product manuals in their support or downloads section.

Proper care ensures long-term accuracy and device longevity. Sensor Care Keep the sensor opening clean and free of dust.

To execute standard field mapping on surfaces, materials, or assembly lines, follow these sequential steps: Simco FMX-002 Electrostatic Fieldmeter Calibration

No Power: Check the battery orientation or replace the battery entirely. Ensure the battery contacts are clean and tight.

+---------------------------------+ | [ LCD DISPLAY ] | | (Bar Graph & Digital Volts) | +---------------------------------+ | [ZERO] [HOLD] [IB] [POWER]| | (Gray) (Green) (Blue) (Red) | +---------------------------------+ | [ SENSOR HEAD ] | | (Ranging Focus LEDs Inside) | +---------------------------------+