Auto-generate SQL statement for CRUD operations on the fly and are completely transparent to the users
By applying conditional formatting to a datagrid cell or row, you can quickly identify variances in a range of values with a quick glance.
A wealth of features including CRUD, WYSIWYG, file upload, autocomplete, composite primary key, and complete export capabilities.
With just one simple function call, you will have an interactive master detail data grid or subgrid.
Creating CRUD manually is time consuming and overwhelming. phpGrid was founded around a simple idea: generating beautiful and editable customized CRUD quickly.
All it takes to make a Perfect CRUD is only 2 LINES OF CODE.
You can enable edit by simply calling enable_edit(). phpGrid supports two types of edit modes, FORM and INLINE.
We think you’ll agree that’s quite impressive for such a minimal amount of code…absolutely minimal coding! phpGrid is the only PHP control that can create jQuery grid without Javascript.
I have come to love and depend on phpGrid for customer web applications, internal administration web apps, and reports and research tools for our many databases. It drastically cuts development time... I couldn't imagine not having phpGrid in our toolbox.
This CRUD tool set allows us to bring information to market faster, and enhances our value to the organization.
| Position | Mode | Description | | :--- | :--- | :--- | | | TEST | Runs the generator through all automatic functions without transferring the load away from the mains power. This allows for a complete system test while the utility supply remains connected. All safety devices remain active. | | 2 | AUTOMATIC MODE | The standard setting for emergency standby. The controller continuously monitors the mains power. If a failure is detected, it automatically starts the generator and transfers the load. | | 3 | LOCK MODE | This setting is used to block certain functions, such as for programming or when maintenance is required. | | 4 | POWER SUPPLY FROM MAINS | Manually forces the system to power the load from the mains supply, regardless of its status. | | 5 | MANUAL START | Bypasses the automatic logic and directly starts the generator using the start push-button. | | 6 | POWER SUPPLY FROM GENERATOR | Manually transfers the load to the generator and powers it, as long as the generator is running. |
: Battery voltage, charging current, and engine working hours.
Modern gensets are often unmanned. The Pramac AC 01 supports multiple remote protocols:
The of your Pramac generator (e.g., Star Series, GSW).
The microprocessor constantly monitors key electrical and mechanical parameters, displaying them on a digital panel: pramac ac 01 generator monitor control system ac01 mp ac01c
This specialized controller manages continuous grid parameter evaluation, sequence operations, and comprehensive engine protection. Whether deployed to manage utility grid dropouts or configured within complex custom automation panels, understanding this controller prevents system downtime and secures facility resilience. Core Hardware Framework & Model Variations
Pramac has designed the AC01 family to be intuitive, but the specific variant you choose changes the game.
Rapid load switching ensures minimal downtime for critical equipment. Intelligence:
The AC01 MP is the standard for basic to mid-range applications. If you need a rugged, no-nonsense controller for a construction site or a backup unit for a small office, this is your unit. | Position | Mode | Description | |
The —whether configured as the rugged AC01C or the grid-interactive AC01 MP —represents a mature, reliable approach to generator control. Its strength lies not in gimmicks, but in robust industrial design, flexible Modbus integration, and a clear evolutionary path from simple standby to complex parallel operation.
The power of the Pramac AC-01 series rests in its dual-domain monitoring capability, providing real-time telemetry across both the mechanical engine side and the electrical alternator/grid side. Alternator and Grid Electrical Metrics
High expansion potential for modems, remote controls, and parallel setups.
: If the utility power drops below a pre-programmed threshold, suffers phase loss, or fails entirely, a failure timer starts. | | 2 | AUTOMATIC MODE | The
System operators configure the system into several distinct operational modes depending on application demands:
: Over-voltage, under-voltage, frequency drift, phase asymmetry, and overload conditions.
The AC-01 provides a comprehensive set of features that go far beyond basic start/stop functionality. It acts as a complete power management solution.
The Pramac AC/01 generator monitor control system is a powerful tool for ensuring the efficient and reliable operation of diesel generators. Its advanced features, benefits, and applications make it a vital component in modern power generation. As technology continues to evolve, the AC/01 is likely to play an increasingly important role in shaping the future of generator management.
: Often denotes specific hardware configurations or updated control boards within the same series, though they share the core operational manual and interface. Resources for Manuals and Support