Skip to content

Lovato 31 Rgam 12 User Manual -

The unit monitors critical engine and alternator functions, displaying codes such as: : Low oil pressure. A02 : Engine overheating. A04 : Failure to start. A05/A06 : Battery voltage anomalies (low/high). Documentation Links

Understanding the Lovato 31 RGAM 12: A Comprehensive Guide The is a specialized automatic mains failure (AMF) controller designed for managing engine-driven generator sets. If you are looking for the "user manual," you are likely trying to install, program, or troubleshoot this specific module.

Access the 255-event log to review past alarms.

If your unit is flashing a code, here are the most frequent ones found in the Lovato RGAM Guide Low Oil Pressure Engine Overheating Low Fuel Level lovato 31 rgam 12 user manual

The is a microprocessor-based Automatic Mains Failure (AMF) control unit engineered by Lovato Electric to automatically manage stand-by generating sets . Operating on a 12VDC auxiliary power supply , this standard 144x144mm panel-mount controller continuously monitors three-phase utility lines and safely transfers power to a single-phase generator when mains anomalies or outages occur.

Setting the "Low Voltage" limit (e.g., 180V on a 230V system) that triggers a start. 6. Troubleshooting Common Issues

Use an infrared camera to check for hot spots on the Lovato controller terminals and capacitor contactors. The unit monitors critical engine and alternator functions,

This guide provides a comprehensive overview of the setup, wiring, and operational parameters found in the Lovato 31 RGAM 12 user manual. 1. Technical Specifications

Most users set these relays for "Under voltage" only, but the manual describes a more protective "Window Mode."

Usually 12VDC or 24VDC (dependent on the specific sub-model). Operating Temperature: -20°C to +60°C. A05/A06 : Battery voltage anomalies (low/high)

The controller senses that utility voltage has dropped below the on any phase for longer than a pre-set delay timer (typically 3–5 seconds). Phase 2: Engine Startup

The time the controller waits after utility power returns to ensure grid stability before transferring the load back (adjustable from 1 to 5 minutes).

Connects to the engine's fuel valve or electronic governor system.

| Parameter | Value | |-----------|-------| | Rated thermal current (Ith) | 12 A | | Rated insulation voltage (Ui) | 690 V AC | | Rated impulse withstand voltage (Uimp) | 6 kV | | Rated operational voltage (Ue) | 240 V AC / 415 V AC (depending on use) | | AC-21A / AC-23A breaking capacity | 12 A | | Mechanical life | > 1,000,000 operations | | Electrical life | > 100,000 operations (rated load) | | Protection degree (front panel) | IP65 (with rubber gasket) | | Operating temperature | -25°C to +60°C | | Terminal type | Screw clamps | | Wire cross-section | 2.5 mm² (flexible/rigid) |