Continue pressing SET until "END" appears on the display. Press SET one last time to save data and return to normal operation. Step (Menu Code) Description Default Value P01 Over-voltage protection value 221V – 300V – OFF P03 Over-voltage recovery value 220V – 299V P04 Under-voltage protection value 150V – 219V – OFF P07 Over-current adjustment 40A/63A/80A 1A – Rated Current P09 Fault recovery delay time 2s – 512s Installation and Wiring
150V–219V (Default: 160V)
This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later.
The Sinotimer SVP-916 is a programmable digital time switch widely utilized in residential, industrial, and agricultural settings for automating electrical circuits. This white paper serves as a surrogate manual, providing users with detailed specifications, wiring diagrams, and step-by-step programming instructions. It addresses common user challenges regarding the interface and offers troubleshooting advice based on the standard operational logic of the SVP-916 platform.
If the protector trips, you can use the feature (detailed in the manual) to understand what caused the disconnection. If the power supply is stable but the protector won't reset, check the P16 parameter; if it's set to 'HA' (manual reset), the device will not automatically restore power when a fault is cleared. Sinotimer Svp-916 Manual Pdf
To enter the programming mode, . Press "Set" sequentially to cycle through the parameters (P1 to P7). Use the ▲ and ▼ keys to adjust the numerical values. Parameter Code Description Adjustable Range Factory Default Value P1 Over-voltage Protection Threshold 221V – 300V (or OFF) P2 Over-voltage Recovery Threshold 220V – 299V P3 Over-voltage Protection Action Time 0.1s – 10s P4 Under-voltage Protection Threshold 150V – 219V (or OFF) P5 Under-voltage Recovery Threshold 151V – 220V P6 Under-voltage Protection Action Time 0.1s – 10s P7 Over-current Protection Threshold 1A – 40A/63A/80A (Model Dep.) Model Maximum P8 Fault Recovery & Boot Delay Time 2s – 512s
Minimum 100,000 switching operations. Installation Format: Standard 35mm DIN rail mounting. Hardware Interface and LED Indicators
The device allows users to customize protection thresholds. To enter settings, typically press the
Automatic reconnection after normal voltage/current resumes. Continue pressing SET until "END" appears on the display
Connect the incoming main power line.
Pressing the **MANUAL
The device features status indicators on the faceplate to help diagnose power issues immediately:
The is an adjustable, automatic over-voltage and under-voltage protection device with an integrated currency meter. It protects sensitive household appliances and industrial equipment from unstable power grids by automatically disconnecting the power supply during voltage spikes or drops and reconnecting it once the grid stabilizes. This link or copies made by others cannot be deleted
The Sinotimer SVP-916 is a popular and highly-regarded timer controller used in a variety of applications, including industrial automation, lighting control, and HVAC systems. If you're looking for a reliable and efficient timer solution, the SVP-916 is definitely worth considering. In this article, we'll provide an in-depth look at the Sinotimer SVP-916, its features, and most importantly, where to find the manual in PDF format.
Indicates the power is cut off due to protection activation. 6. Troubleshooting
An interesting technical note in the SVP-916 Manual warns that if the under-voltage action time is set higher than 0.3 seconds , the internal microcontroller (MCU) might lose power during a drop before it can successfully trigger the relay to disconnect the circuit.